Chapter 5 — Using the IF61 GPIO Interfaces
IF61 Fixed Reader User’s Manual 117
Open Collector Input Interface
Using the Output Interfaces
Each IF61 output interface is optically isolated from the IF61,
polarized, and rated for 5 to 48 VDC at 0.25 A. All IF61 outputs
include internal thermal fuses that trip if the load exceeds 0.25 A, and
the fuses are self-recovering once the excessive load is removed. The
high and low contacts are exposed and isolated from ground.
Transient suppression limits output voltage spikes to 65 VDC.
Because the outputs are optically isolated, each one can be configured
to switch the high side or the low side of the load. You can power the
load directly from the IF61 or from an external power supply.
In a typical application, the outputs control indicator lamps that
signal good reads or errors. The basic methods for connecting
external devices to the GPIO outputs include:
Switching the high side, with the load powered by the IF61
Switching the low side, with the load powered by the IF61
Switching the high side, with the load powered externally
Driving a DC relay that controls an AC load
+Input
+12V
Ground
- Input
GPIO Output Specifications
Signal Description Min. Typical Max.
Leakage
current (High)
Switch output, high leakage
current
0 mA 1 mA 10 mA
V
sat
(Low) Switch output on, saturation
voltage with 0.25A load
0V 1V 1.5V